The Open Group Base Specifications Issue 7, 2018 edition
IEEE Std 1003.1-2017 (Revision of IEEE Std 1003.1-2008)
Copyright © 2001-2018 IEEE and The Open Group

NAME

cflow - generate a C-language flowgraph (DEVELOPMENT)

SYNOPSIS

[XSI] [Option Start] cflow [-r] [-d num] [-D name[=def]]... [-i incl] [-I dir]...
      
[-U dir]... file... [Option End]

DESCRIPTION

The cflow utility shall analyze a collection of object files or assembler, C-language, lex, or yacc source files, and attempt to build a graph, written to standard output, charting the external references.

OPTIONS

The cflow utility shall conform to XBD Utility Syntax Guidelines, except that the order of the -D, -I, and -U options (which are identical to their interpretation by c99) is significant.

The following options shall be supported:

-d  num
Indicate the depth at which the flowgraph is cut off. The application shall ensure that the argument num is a decimal integer. By default this is a very large number (typically greater than 32000). Attempts to set the cut-off depth to a non-positive integer shall be ignored.
-i  incl
Increase the number of included symbols. The incl option-argument is one of the following characters:
x
Include external and static data symbols. The default shall be to include only functions in the flowgraph.
_
(Underscore) Include names that begin with an <underscore>. The default shall be to exclude these functions (and data if -i x is used).
-r
Reverse the caller:callee relationship, producing an inverted listing showing the callers of each function. The listing shall also be sorted in lexicographical order by callee.

OPERANDS

The following operand is supported:

file
The pathname of a file for which a graph is to be generated. Filenames suffixed by .l shall shall be taken to be lex input, .y as yacc input, .c as c99 input, and .i as the output of c99 -E. Such files shall be processed as appropriate, determined by their suffix.

Files suffixed by .s (conventionally assembler source) may have more limited information extracted from them.

STDIN

Not used.

INPUT FILES

The input files shall be object files or assembler, C-language, lex, or yacc source files.

ENVIRONMENT VARIABLES

The following environment variables shall affect the execution of cflow:

LANG
Provide a default value for the internationalization variables that are unset or null. (See XBD Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
LC_ALL
If set to a non-empty string value, override the values of all the other internationalization variables.
LC_COLLATE
Determine the locale for the ordering of the output when the -r option is used.
LC_CTYPE
Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments and input files).
LC_MESSAGES
Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error.
NLSPATH
Determine the location of message catalogs for the processing of LC_MESSAGES.

ASYNCHRONOUS EVENTS

Default.

STDOUT

The flowgraph written to standard output shall be formatted as follows:

"%d %s:%s\n", <reference number>, <global>, <definition>

Each line of output begins with a reference (that is, line) number, followed by indentation of at least one column position per level. This is followed by the name of the global, a <colon>, and its definition. Normally globals are only functions not defined as an external or beginning with an <underscore>; see the OPTIONS section for the -i inclusion option. For information extracted from C-language source, the definition consists of an abstract type declaration (for example, char *) and, delimited by angle brackets, the name of the source file and the line number where the definition was found. Definitions extracted from object files indicate the filename and location counter under which the symbol appeared (for example, text).

Once a definition of a name has been written, subsequent references to that name contain only the reference number of the line where the definition can be found. For undefined references, only "<>" shall be written.

STDERR

The standard error shall be used only for diagnostic messages.

OUTPUT FILES

None.

EXTENDED DESCRIPTION

None.

EXIT STATUS

The following exit values shall be returned:

 0
Successful completion.
>0
An error occurred.

CONSEQUENCES OF ERRORS

Default.


The following sections are informative.

APPLICATION USAGE

Files produced by lex and yacc cause the reordering of line number declarations, and this can confuse cflow. To obtain proper results, the input of yacc or lex must be directed to cflow.

EXAMPLES

Given the following in file.c:

int i;
int f();
int g();
int h();
int
main()
{
    f();
    g();
    f();
}
int
f()
{
    i = h();
}

The command:

cflow -i x file.c

produces the output:

1 main: int(), <file.c 6>
2    f: int(), <file.c 13>
3        h: <>
4        i: int, <file.c 1>
5    g: <>

RATIONALE

None.

FUTURE DIRECTIONS

None.

SEE ALSO

c99, lex, yacc

XBD Environment Variables, Utility Syntax Guidelines

CHANGE HISTORY

First released in Issue 2.

Issue 6

The normative text is reworded to avoid use of the term "must" for application requirements.

Issue 7

SD5-XCU-ERN-97 is applied, updating the SYNOPSIS.

End of informative text.

 

return to top of page

UNIX ® is a registered Trademark of The Open Group.
POSIX ™ is a Trademark of The IEEE.
Copyright © 2001-2018 IEEE and The Open Group, All Rights Reserved
[ Main Index | XBD | XSH | XCU | XRAT ]