The Open Group Base Specifications Issue 7
IEEE Std 1003.1-2008
Copyright © 2001-2008 The IEEE and The Open Group

NAME

msync - synchronize memory with physical storage

SYNOPSIS

[XSI|SIO] [Option Start] #include <sys/mman.h>

int msync(void *
addr, size_t len, int flags); [Option End]

DESCRIPTION

The msync() function shall write all modified data to permanent storage locations, if any, in those whole pages containing any part of the address space of the process starting at address addr and continuing for len bytes. If no such storage exists, msync() need not have any effect. If requested, the msync() function shall then invalidate cached copies of data.

The implementation may require that addr be a multiple of the page size as returned by sysconf().

For mappings to files, the msync() function shall ensure that all write operations are completed as defined for synchronized I/O data integrity completion. It is unspecified whether the implementation also writes out other file attributes. When the msync() function is called on MAP_PRIVATE mappings, any modified data shall not be written to the underlying object and shall not cause such data to be made visible to other processes. It is unspecified whether data in MAP_PRIVATE mappings has any permanent storage locations. [SHM|TYM] [Option Start]  The effect of msync() on a shared memory object or a typed memory object is unspecified. [Option End] The behavior of this function is unspecified if the mapping was not established by a call to mmap().

The flags argument is constructed from the bitwise-inclusive OR of one or more of the following flags defined in the <sys/mman.h> header:

Symbolic Constant

Description

MS_ASYNC

Perform asynchronous writes.

MS_SYNC

Perform synchronous writes.

MS_INVALIDATE

Invalidate cached data.

When MS_ASYNC is specified, msync() shall return immediately once all the write operations are initiated or queued for servicing; when MS_SYNC is specified, msync() shall not return until all write operations are completed as defined for synchronized I/O data integrity completion. Either MS_ASYNC or MS_SYNC shall be specified, but not both.

When MS_INVALIDATE is specified, msync() shall invalidate all cached copies of mapped data that are inconsistent with the permanent storage locations such that subsequent references shall obtain data that was consistent with the permanent storage locations sometime between the call to msync() and the first subsequent memory reference to the data.

If msync() causes any write to a file, the file's last data modification and last file status change timestamps shall be marked for update.

RETURN VALUE

Upon successful completion, msync() shall return 0; otherwise, it shall return -1 and set errno to indicate the error.

ERRORS

The msync() function shall fail if:

[EBUSY]
Some or all of the addresses in the range starting at addr and continuing for len bytes are locked, and MS_INVALIDATE is specified.
[EINVAL]
The value of flags is invalid.
[ENOMEM]
The addresses in the range starting at addr and continuing for len bytes are outside the range allowed for the address space of a process or specify one or more pages that are not mapped.

The msync() function may fail if:

[EINVAL]
The value of addr is not a multiple of the page size as returned by sysconf().

The following sections are informative.

EXAMPLES

None.

APPLICATION USAGE

The msync() function is only supported if the Synchronized Input and Output option is supported, and thus need not be available on all implementations.

The msync() function should be used by programs that require a memory object to be in a known state; for example, in building transaction facilities.

Normal system activity can cause pages to be written to disk. Therefore, there are no guarantees that msync() is the only control over when pages are or are not written to disk.

RATIONALE

The msync() function writes out data in a mapped region to the permanent storage for the underlying object. The call to msync() ensures data integrity of the file.

After the data is written out, any cached data may be invalidated if the MS_INVALIDATE flag was specified. This is useful on systems that do not support read/write consistency.

FUTURE DIRECTIONS

None.

SEE ALSO

mmap , sysconf

XBD <sys/mman.h>

CHANGE HISTORY

First released in Issue 4, Version 2.

Issue 5

Moved from X/OPEN UNIX extension to BASE.

Aligned with msync() in the POSIX Realtime Extension as follows:

Issue 6

The msync() function is marked as part of the Memory Mapped Files and Synchronized Input and Output options.

The following changes are made for alignment with the ISO POSIX-1:1996 standard:

The following new requirements on POSIX implementations derive from alignment with the Single UNIX Specification:

The DESCRIPTION is updated for alignment with IEEE Std 1003.1j-2000 by adding reference to typed memory objects.

Issue 7

Austin Group Interpretation 1003.1-2001 #078 is applied, clarifying page alignment requirements.

SD5-XSH-ERN-110 is applied.

The msync() function is marked as part of the Synchronized Input and Output option or XSI option as the Memory Mapped Files is moved to the Base.

Changes are made related to support for finegrained timestamps.

End of informative text.

 

return to top of page

UNIX ® is a registered Trademark of The Open Group.
POSIX ® is a registered Trademark of The IEEE.
Copyright © 2001-2008 The IEEE and The Open Group, All Rights Reserved
[ Main Index | XBD | XSH | XCU | XRAT ]