The Open Group Base Specifications Issue 7, 2018 edition
IEEE Std 1003.1-2017 (Revision of IEEE Std 1003.1-2008)
Copyright © 2001-2018 IEEE and The Open Group

NAME

pow, powf, powl - power function

SYNOPSIS

#include <math.h>

double pow(double
x, double y);
float powf(float
x, float y);
long double powl(long double
x, long double y);

DESCRIPTION

[CX] [Option Start] The functionality described on this reference page is aligned with the ISO C standard. Any conflict between the requirements described here and the ISO C standard is unintentional. This volume of POSIX.1-2017 defers to the ISO C standard. [Option End]

These functions shall compute the value of x raised to the power y, xy. If x is negative, the application shall ensure that y is an integer value.

An application wishing to check for error situations should set errno to zero and call feclearexcept(FE_ALL_EXCEPT) before calling these functions. On return, if errno is non-zero or fetestexcept(FE_INVALID | FE_DIVBYZERO | FE_OVERFLOW | FE_UNDERFLOW) is non-zero, an error has occurred.

RETURN VALUE

Upon successful completion, these functions shall return the value of x raised to the power y.

For finite values of x < 0, and finite non-integer values of y, a domain error shall occur and [MX] [Option Start]  either a NaN (if representable), or [Option End] an implementation-defined value shall be returned.

If the correct value would cause overflow, a range error shall occur and pow(), powf(), and powl() shall return ±HUGE_VAL, ±HUGE_VALF, and ±HUGE_VALL, respectively, with the same sign as the correct value of the function.

If the correct value would cause underflow, [MXX] [Option Start]  and is not representable, [Option End]  a range error may occur, and pow(), powf(), and powl() shall return [MXX] [Option Start]  0.0, or [Option End]  (if IEC 60559 Floating-Point is not supported) an implementation-defined value no greater in magnitude than DBL_MIN, FLT_MIN, and LDBL_MIN, respectively.

For y < 0, if x is zero, a [CX] [Option Start]  pole [Option End]  error may occur and pow(), powf(), and powl() shall return ±HUGE_VAL, ±HUGE_VALF, and ±HUGE_VALL, respectively. [MX] [Option Start]  On systems that support the IEC 60559 Floating-Point option, if x is ±0, a pole error shall occur and pow(), powf(), and powl() shall return ±HUGE_VAL, ±HUGE_VALF, and ±HUGE_VALL, respectively if y is an odd integer, or HUGE_VAL, HUGE_VALF, and HUGE_VALL, respectively if y is not an odd integer. [Option End]

[MX] [Option Start] If x or y is a NaN, a NaN shall be returned (unless specified elsewhere in this description).

For any value of y (including NaN), if x is +1, 1.0 shall be returned.

For any value of x (including NaN), if y is ±0, 1.0 shall be returned.

For any odd integer value of y > 0, if x is ±0, ±0 shall be returned.

For y > 0 and not an odd integer, if x is ±0, +0 shall be returned.

If x is -1, and y is ±Inf, 1.0 shall be returned.

For |x| < 1, if y is -Inf, +Inf shall be returned.

For |x| > 1, if y is -Inf, +0 shall be returned.

For |x| < 1, if y is +Inf, +0 shall be returned.

For |x| > 1, if y is +Inf, +Inf shall be returned.

For y an odd integer < 0, if x is -Inf, -0 shall be returned.

For y < 0 and not an odd integer, if x is -Inf, +0 shall be returned.

For y an odd integer > 0, if x is -Inf, -Inf shall be returned.

For y > 0 and not an odd integer, if x is -Inf, +Inf shall be returned.

For y < 0, if x is +Inf, +0 shall be returned.

For y > 0, if x is +Inf, +Inf shall be returned. [Option End]

[MXX] [Option Start] If the correct value would cause underflow, and is representable, a range error may occur and the correct value shall be returned. [Option End]

ERRORS

These functions shall fail if:

Domain Error
The value of x is negative and y is a finite non-integer.

If the integer expression (math_errhandling & MATH_ERRNO) is non-zero, then errno shall be set to [EDOM]. If the integer expression (math_errhandling & MATH_ERREXCEPT) is non-zero, then the invalid floating-point exception shall be raised.

Pole Error
[MX] [Option Start] The value of x is zero and y is negative.

If the integer expression (math_errhandling & MATH_ERRNO) is non-zero, then errno shall be set to [ERANGE]. If the integer expression (math_errhandling & MATH_ERREXCEPT) is non-zero, then the divide-by-zero floating-point exception shall be raised. [Option End]

Range Error
The result overflows.

If the integer expression (math_errhandling & MATH_ERRNO) is non-zero, then errno shall be set to [ERANGE]. If the integer expression (math_errhandling & MATH_ERREXCEPT) is non-zero, then the overflow floating-point exception shall be raised.

These functions may fail if:

Pole Error
The value of x is zero and y is negative.

If the integer expression (math_errhandling & MATH_ERRNO) is non-zero, then errno shall be set to [ERANGE]. If the integer expression (math_errhandling & MATH_ERREXCEPT) is non-zero, then the divide-by-zero floating-point exception shall be raised.

Range Error
The result underflows.

If the integer expression (math_errhandling & MATH_ERRNO) is non-zero, then errno shall be set to [ERANGE]. If the integer expression (math_errhandling & MATH_ERREXCEPT) is non-zero, then the underflow floating-point exception shall be raised.


The following sections are informative.

EXAMPLES

None.

APPLICATION USAGE

On error, the expressions (math_errhandling & MATH_ERRNO) and (math_errhandling & MATH_ERREXCEPT) are independent of each other, but at least one of them must be non-zero.

RATIONALE

None.

FUTURE DIRECTIONS

None.

SEE ALSO

exp, feclearexcept, fetestexcept, isnan

XBD Treatment of Error Conditions for Mathematical Functions, <math.h>

CHANGE HISTORY

First released in Issue 1. Derived from Issue 1 of the SVID.

Issue 5

The DESCRIPTION is updated to indicate how an application should check for an error. This text was previously published in the APPLICATION USAGE section.

Issue 6

The normative text is updated to avoid use of the term "must" for application requirements.

The powf() and powl() functions are added for alignment with the ISO/IEC 9899:1999 standard.

The DESCRIPTION, RETURN VALUE, ERRORS, and APPLICATION USAGE sections are revised to align with the ISO/IEC 9899:1999 standard.

IEC 60559:1989 standard floating-point extensions over the ISO/IEC 9899:1999 standard are marked.

IEEE Std 1003.1-2001/Cor 1-2002, item XSH/TC1/D6/42 is applied, correcting the third paragraph in the RETURN VALUE section.

Issue 7

ISO/IEC 9899:1999 standard, Technical Corrigendum 2 #51 (SD5-XSH-ERN-81) is applied.

POSIX.1-2008, Technical Corrigendum 1, XSH/TC1-2008/0443 [68], XSH/TC1-2008/0444 [148], and XSH/TC1-2008/0445 [68] are applied.

End of informative text.

 

return to top of page

UNIX ® is a registered Trademark of The Open Group.
POSIX ™ is a Trademark of The IEEE.
Copyright © 2001-2018 IEEE and The Open Group, All Rights Reserved
[ Main Index | XBD | XSH | XCU | XRAT ]